Proven Performance · Precision Measurement Record

KXVT2003 R0.15 Micro-Diameter Precision Comparison

A 15-record radius-deviation comparison covering KXT KXVT2003 R0.15 0450·V·G EXS, NS MRBH 230 R0.15*0.5 and a domestic major-brand R0.15*0.5 reference. Every printed reading from the source board is reproduced below together with its measurement screenshot.

Test purpose: Micro-diameter machining precision comparison Nominal radius: R0.15 Evidence: 15 recorded measurement screenshots

Fifteen measurement screenshots comparing KXT KXVT2003, NS MRBH 230 and a domestic major-brand R0.15 reference
The complete 15-image measurement grid from the supplied precision-comparison record.
KXT Tool
KXVT2003 R0.15 0450·V·G EXS
Groups
3
Records
15
Per Group
5
Source-Marked Exceptions
3 domestic-brand records

Recorded Comparison

What the 15 Measurement Records Show

The three summary envelopes below are derived only from the minimum and maximum values printed on the supplied comparison board. No missing machining conditions or tolerance threshold have been invented.

02 · NS Reference

NS MRBH 230 R0.15*0.5

−0.0015 to +0.0010

Five printed measurement ranges. None of the five NS reference records is marked out of tolerance on the source board.

03 · Domestic Reference

Domestic major brand R0.15*0.5

−0.0055 to +0.0050

Five printed measurement ranges. Samples 2, 3 and 5 are explicitly highlighted and marked “out of tolerance” in the supplied source record.

Auditable Data

All 15 Radius-Deviation Readings

“Source reading” keeps the measurement values exactly as shown in the supplied board. The minimum and maximum columns simply split each printed range into numeric endpoints for easier engineering review.

Complete measurement transcription from the supplied micro-diameter precision comparison
Group Sample Source reading Minimum Maximum Source status
KXT KXVT2003 1 R±0.001 -0.0010 +0.0010 Not marked
KXT KXVT2003 2 R-0.0013 ~ +0.0008 -0.0013 +0.0008 Not marked
KXT KXVT2003 3 R-0.0015 ~ +0.0008 -0.0015 +0.0008 Not marked
KXT KXVT2003 4 R-0.0013 ~ +0.0005 -0.0013 +0.0005 Not marked
KXT KXVT2003 5 R-0.0015 ~ +0.0005 -0.0015 +0.0005 Not marked
NS reference 11 R-0.001 ~ +0.0005 -0.0010 +0.0005 Not marked
NS reference 12 R-0.0015 ~ +0.0003 -0.0015 +0.0003 Not marked
NS reference 13 R-0.001 ~ +0.0005 -0.0010 +0.0005 Not marked
NS reference 14 R±0.001 -0.0010 +0.0010 Not marked
NS reference 15 R-0.0015 ~ +0.0005 -0.0015 +0.0005 Not marked
Domestic major brand 1 R-0.003 ~ +0.005 -0.0030 +0.0050 Not marked
Domestic major brand 2 R-0.0035 ~ +0.0008 -0.0035 +0.0008 Out of tolerance*
Domestic major brand 3 R-0.0053 ~ +0.002 -0.0053 +0.0020 Out of tolerance*
Domestic major brand 4 R-0.003 ~ +0.0008 -0.0030 +0.0008 Not marked
Domestic major brand 5 R-0.0055 ~ +0.0005 -0.0055 +0.0005 Out of tolerance*

*Tolerance note: the source board explicitly marks only domestic major-brand samples 2, 3 and 5 as out of tolerance. It does not print the numerical tolerance limit, so this page reproduces those markings without inferring a threshold that is not present in the source.

Measurement Evidence

Original Measurement Screenshots by Tool Group

Each image is cropped directly from the supplied comparison board. The visible measurement reading remains in the crop so the page text can be checked against the source image.

KXT measurement set

KXVT2003 R0.15 0450·V·G EXS

Overall recorded envelope: −0.0015 to +0.0010. Five recorded measurements; none is marked out of tolerance on the source board.

KXVT2003 R0.15 0450·V·G EXS sample 1 measurement screenshot showing R±0.001
Sample 1 R±0.001 No out-of-tolerance mark
KXVT2003 R0.15 0450·V·G EXS sample 2 measurement screenshot showing R-0.0013 ~ +0.0008
Sample 2 R-0.0013 ~ +0.0008 No out-of-tolerance mark
KXVT2003 R0.15 0450·V·G EXS sample 3 measurement screenshot showing R-0.0015 ~ +0.0008
Sample 3 R-0.0015 ~ +0.0008 No out-of-tolerance mark
KXVT2003 R0.15 0450·V·G EXS sample 4 measurement screenshot showing R-0.0013 ~ +0.0005
Sample 4 R-0.0013 ~ +0.0005 No out-of-tolerance mark
KXVT2003 R0.15 0450·V·G EXS sample 5 measurement screenshot showing R-0.0015 ~ +0.0005
Sample 5 R-0.0015 ~ +0.0005 No out-of-tolerance mark
Reference measurement set

NS MRBH 230 R0.15*0.5

Overall recorded envelope: −0.0015 to +0.0010. Five recorded measurements; none is marked out of tolerance on the source board.

NS MRBH 230 R0.15*0.5 sample 11 measurement screenshot showing R-0.001 ~ +0.0005
Sample 11 R-0.001 ~ +0.0005 No out-of-tolerance mark
NS MRBH 230 R0.15*0.5 sample 12 measurement screenshot showing R-0.0015 ~ +0.0003
Sample 12 R-0.0015 ~ +0.0003 No out-of-tolerance mark
NS MRBH 230 R0.15*0.5 sample 13 measurement screenshot showing R-0.001 ~ +0.0005
Sample 13 R-0.001 ~ +0.0005 No out-of-tolerance mark
NS MRBH 230 R0.15*0.5 sample 14 measurement screenshot showing R±0.001
Sample 14 R±0.001 No out-of-tolerance mark
NS MRBH 230 R0.15*0.5 sample 15 measurement screenshot showing R-0.0015 ~ +0.0005
Sample 15 R-0.0015 ~ +0.0005 No out-of-tolerance mark
Domestic comparison set

Domestic major brand R0.15*0.5

Overall recorded envelope: −0.0055 to +0.0050. Five recorded measurements; samples 2, 3 and 5 are explicitly marked out of tolerance on the source board.

Domestic major brand R0.15*0.5 sample 1 measurement screenshot showing R-0.003 ~ +0.005
Sample 1 R-0.003 ~ +0.005 No out-of-tolerance mark
Domestic major brand R0.15*0.5 sample 2 measurement screenshot showing R-0.0035 ~ +0.0008
Sample 2 R-0.0035 ~ +0.0008 Source-marked out of tolerance
Domestic major brand R0.15*0.5 sample 3 measurement screenshot showing R-0.0053 ~ +0.002
Sample 3 R-0.0053 ~ +0.002 Source-marked out of tolerance
Domestic major brand R0.15*0.5 sample 4 measurement screenshot showing R-0.003 ~ +0.0008
Sample 4 R-0.003 ~ +0.0008 No out-of-tolerance mark
Domestic major brand R0.15*0.5 sample 5 measurement screenshot showing R-0.0055 ~ +0.0005
Sample 5 R-0.0055 ~ +0.0005 Source-marked out of tolerance

Interpretation & Scope

How to Read This Precision Comparison

Source purpose
The supplied record defines the test purpose as a micro-diameter machining precision comparison across domestic and overseas brands, using actual measurement data to compare dimensional precision and stability.
Source conclusion
The original board summarizes KXVT·V·G EXS as showing more stable and reliable micro-diameter precision. This web page preserves that source conclusion while also exposing every printed reading for independent review.
Numeric comparison
From the printed extrema alone, the KXT and NS groups share the same overall recorded envelope of −0.0015 to +0.0010. The domestic major-brand group is visibly wider at −0.0055 to +0.0050 and includes three source-marked out-of-tolerance records.
Missing conditions
The supplied board does not state workpiece material, hardness, machine, holder, spindle speed, feed, depth of cut, coolant condition or a numeric tolerance threshold. Those items are therefore not added to this case page.
Use of result
These 15 screenshots document this specific comparison set. They should be used as application evidence rather than as a universal accuracy guarantee for every machine, runout condition, toolpath or workpiece.
KXT KXVT2003 R0.15 micro-diameter precision comparison with 15 real measurement screenshots and English result summary
English presentation board recreated from the supplied precision-comparison record. The 15 measurement screenshots and printed values remain the evidence basis for this page; no unreported machining parameters or tolerance threshold have been added.

Application Questions

KXVT2003 R0.15 Precision Comparison FAQ

Direct answers written from the supplied measurements so engineers and search systems can retrieve the key facts without losing the source context.

What tools are included in this micro-diameter precision comparison?

The record compares KXT KXVT2003 R0.15 0450·V·G EXS, NS MRBH 230 R0.15*0.5 and a domestic major-brand R0.15*0.5 reference. There are five measurement screenshots for each group, for a total of 15 records.

What readings were recorded for KXT KXVT2003?

The five KXT readings are R±0.001, R-0.0013 to +0.0008, R-0.0015 to +0.0008, R-0.0013 to +0.0005 and R-0.0015 to +0.0005.

Were any KXT KXVT2003 records marked out of tolerance?

No. None of the five KXT records carries the source board's yellow “out of tolerance” marking. The NS reference records are also not marked out of tolerance in the supplied comparison board.

Which comparison records are marked out of tolerance?

In the domestic major-brand group, samples 2, 3 and 5 are explicitly marked out of tolerance. Their printed readings are R-0.0035 to +0.0008, R-0.0053 to +0.002 and R-0.0055 to +0.0005 respectively.

Does the source board provide the numerical tolerance limit?

No. It identifies three domestic-brand measurements as out of tolerance but does not print the numerical acceptance limit. This page therefore reproduces the source markings without inventing a tolerance threshold.

What information is needed to reproduce a similar micro-tool trial?

For a controlled comparison, provide the workpiece material and hardness, exact tool geometry, holder and measured runout, machine model, spindle speed, feed, axial and radial engagement, coolant condition, target dimensional tolerance and the measurement method used for acceptance.

Review a Micro-Diameter Precision Application

Send your target radius or diameter, workpiece material, machine setup, measured runout, cutting data and dimensional acceptance criteria. KXT can review the application and prepare a controlled tool-test recommendation.